| Indoor unit | ASTG34KMTC |
| Outdoor unit | AOTG34KMTC |
| Operation Type | Reverse Cycle |
| Power Source V/Ph/Hz | 230 / 1 / 50 |
| Cooling Capacity kW (Rated (Min – Max)) | 9.40 (2.9 – 11.2) |
| Heating Capacity kW (Rated (Min – Max)) | 10.30 (2.7 – 11.7) |
| Input Power Cooling kW (Rated (Min – Max)) | 2.78 (0.59 – 4.03) |
| Input Power Heating kW (Rated (Min – Max)) | 2.84 (0.6 – 4.24) |
| EER Cooling kW/kW | 3.38 |
| COP Heating kW/kW | 3.63 |
| Star Rating Cooling (0-10) (Hot / Average / Cold) | 3 / 2.5 / 2.5 |
| Star Rating Heating (0-10) (Hot / Average / Cold) | 2 / 2 / 1.5 |
| Total Cooling Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 4.628 / 4.317 / 4.482 |
| Heating Seasonal Performance Factor Residential kW (Hot / Average / Cold) | 3.834 / 3.603 / 3.312 |
| Total Cooling Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 5.018 / 5.153 / 5.599 |
| Heating Seasonal Performance Factor Commercial kW (Hot / Average / Cold) | 3.823 / 3.676 / 3.433 |
| Running Current amps (Cooling / Heating) | 11.7 / 11.9 |
| Moisture Removal l/hr | 3.5 |
| Indoor Sound Pressure Cooling dBA (High / Quiet) | 52 / 34 |
| Indoor Sound Pressure Heating dBA (High / Quiet) | 51 / 33 |
| Outdoor Sound Pressure dBA (Cooling / Heating) | 50 / 54 |
| Outdoor Sound Power dBA | 65 |
| Air Circulation (Indoor – High Fan) Cooling l/sec | 389 |
| Air Circulation (Indoor – High Fan) Heating l/sec | 389 |
| Indoor Unit Dimensions mm (Height x Width x Depth) | 340 x 1150 x 280 |
| Indoor Unit Weight kg | 18 |
| Outdoor Unit Dimensions mm (Height x Width x Depth) | 914 x 970 x 370 |
| Outdoor Unit Weight kg | 74 |
| Piping Connects mm Ø (Liquid / Gas) | 9.52 / 15.88 |
| Pipe Length m (Max (Precharged)) | 75 (30) |
| Max Height Difference m | 30 |
| Operation Range Cooling °CDB (Min to Max) | -10 to 46 |
| Operation Range Heating °CDB (Min to Max) | -15 to 24 |
| Refrigerant Type | R32 |
| Refrigerant Amount g | 2,000 |